Fire
resistance test – FOAM in
board construction lasted
for 93 minutes.
Type
of document:
Fire
Resistance Test
Title:
YARSLEY
Fire Resistance Test
Identification:
Certificate
No. C72618/1
Comments:
Fire
resistance test on DOORS which
contained foam with “Leica” balls.
Door lasted for 48 minutes (insulation),
61 minutes (integrity).
Type
of document:
Fire
Test on doors
Title:
TRADA
Report of an Indicative Fire Resistance
Test Performed on Three Door Panels
Identification:
IT
175
Comments:
Fire
tests on 3 panel doors. Insulation & stability
from 48 to 83 minutes.
Type
of document:
Fire
Resistance Test on door
Title:
YARSLEY
Fire Resistance Tests to BS 476:
Part 8: 1972
Identification:
Certificate
No.C73645/1
Comments:
Fire
test on a door. Stability 33 minutes;
Integrity 26 minutes; Insulation
26 minutes.
Type
of document:
Fire
Test on door
Title:
TRADA
Report of a Fire Resistance Test
Performed on a Double Acting Double
Leaf Doorset
Identification:
TRADA
FR 742
Comments:
Fire
test on door – foam density
650 kg/m3 – covered with oak
veneer. Stability 66 minutes; Integrity
62 minutes; Insulation 48 minutes.
Type
of document:
Certificate
of Test
Title:
TRADA
Certificate of Test for FR 742
Identification:
TRADA
FR 742
Comments:
Fire
test on door – foam density
650 kg/m3 – covered with oak
veneer. Stability 66 minutes; Integrity
62 minutes; Insulation 48 minutes.
Type
of document:
Fire
Test on Jesmonite
Title:
YARSLEY
Surface Spread of Flame Tests for
Materials to BS 476: Part 7: 1971
Identification:
J77107/1
Comments:
Test
for SURFACE SPREAD OF FLAME. Test
on JESMONITE. No spread of flame
at all.
Type
of document:
Fire
Test on Door
Title:
TRADA
Report of a Fire Resistance Test
Performed on Two Latched, Single
Acting, Single Leaf Doorsets
Identification:
TRADA
FR 1007
Comments:
Fire
resistance on 2 doors. Foam density
200 kg/m3 covered with Gypsum, with
wood veneer. Stability & etc.
44-46 minutes
Type
of document:
Fire
Resistance Test
Title:
YARSLEY
Fire resistance Test to BS 476: Part
8: 1972 on an Acell Door and Timber
Frame
Identification:
J
80708/1
Comments:
Fire
resistance on door. Foam density
300 kg/m3 with GRP coat – no
veneer. Stability 29 minutes; Integrity
14 minutes; Insulation 14 minutes.
Type
of document:
Fire
Test on Foam
Title:
YARSLEY
Surface Spread of Flame Tests for
Materials to BS 476: Part 7: 1971
on a sample of Acell Structural Composite
Foam
Identification:
B79331/6
Comments:
SURFACE
SPREAD OF FLAME on foam 340 kg/m3.
No ignition, only charring observed.
Type
of document:
Fire
Test on Foam
Title:
YARSLEY
Fire Propagation Test to BS 476:
Part 6: 1981 On a sample Of Acell
Structural Composite Foam
Identification:
B79331/7
Comments:
Fire
propagation index measure
Type
of document:
Fire
Resistance Test
Title:
SGS Yarsley
Technical Service
Identification:
Test
report J90358/1
Comments:
Door
sandwich construction of Acell
material and glass reinforced Gypsum
in a doorset..
Integrity & Insulation
42 minutes.
Type
of document:
Fire
resistance
Title:
Fire
Resistance Test in Accordance with
BS 476: Part 22: 1987, clause 6,
on a Fully Insulated, Single-Acting
Single-Leaf Doorset.
(Warrington