Type of document:

Certificate of Test
Title:
YARSLEY Fire Resistance Test
Identification: FR 554
Comments: Fire resistance test – FOAM in board construction  lasted for 93 minutes.

Type of document:

Fire Resistance Test
Title:
YARSLEY Fire Resistance Test
Identification: Certificate No. C72618/1
Comments: Fire resistance test on DOORS which contained foam with “Leica” balls. Door lasted for 48 minutes (insulation), 61 minutes (integrity).

Type of document:

Fire Test on doors
Title:
TRADA Report of an Indicative Fire Resistance Test Performed on Three Door Panels
Identification: IT 175
Comments: Fire tests on 3 panel doors. Insulation & stability from 48 to 83 minutes.

Type of document:

Fire Resistance Test on door
Title:
YARSLEY Fire Resistance Tests to BS 476: Part 8: 1972
Identification:

Certificate No.C73645/1

Comments: Fire test on a door. Stability 33 minutes; Integrity 26 minutes; Insulation 26 minutes.

Type of document:

Fire Test  on door
Title:
TRADA Report of a Fire Resistance Test Performed on a Double Acting Double Leaf Doorset
Identification:

TRADA FR 742

Comments: Fire test on door – foam density 650 kg/m3 – covered with oak veneer. Stability 66 minutes; Integrity 62 minutes; Insulation 48 minutes.

Type of document:

Certificate of Test
Title:
TRADA Certificate of Test for FR 742
Identification:

TRADA FR 742

Comments: Fire test on door – foam density 650 kg/m3 – covered with oak veneer. Stability 66 minutes; Integrity 62 minutes; Insulation 48 minutes.

Type of document:

Fire Test on Jesmonite
Title:
YARSLEY Surface Spread of Flame Tests for Materials to BS 476: Part 7: 1971
Identification:

J77107/1

Comments: Test for SURFACE SPREAD OF FLAME. Test on JESMONITE. No spread of flame at all.

Type of document:

Fire Test on Door
Title:
TRADA Report of a Fire Resistance Test Performed on Two Latched, Single Acting, Single Leaf Doorsets
Identification:

TRADA FR 1007

Comments: Fire resistance on 2 doors. Foam density 200 kg/m3 covered with Gypsum, with wood veneer. Stability & etc. 44-46 minutes

Type of document:

Fire Resistance Test
Title:
YARSLEY Fire resistance Test to BS 476: Part 8: 1972 on an Acell Door and Timber Frame
Identification:

J 80708/1

Comments: Fire resistance on door. Foam density 300 kg/m3 with GRP coat – no veneer. Stability 29 minutes; Integrity 14 minutes; Insulation 14 minutes.

Type of document:

Fire Test on Foam
Title:
YARSLEY Surface Spread of Flame Tests for Materials to BS 476: Part 7: 1971 on a sample of Acell Structural Composite Foam
Identification:

B79331/6

Comments: SURFACE SPREAD OF FLAME on foam 340 kg/m3. No ignition, only charring observed.

Type of document:

Fire Test on Foam
Title:
YARSLEY Fire Propagation Test to BS 476: Part 6: 1981 On a sample Of Acell Structural Composite Foam
Identification:

B79331/7

Comments: Fire propagation index measure

Type of document:

Fire Resistance Test
Title:
SGS  Yarsley Technical Service
Identification:

Test report J90358/1

Comments:

Door sandwich construction of Acell material and glass reinforced Gypsum in a doorset..
Integrity & Insulation 42 minutes.

Type of document:

Fire resistance
Title:

Fire Resistance Test in Accordance with BS 476: Part 22: 1987, clause 6, on a Fully Insulated, Single-Acting Single-Leaf Doorset.
(Warrington Fire Research)

Identification:

 

Comments:

GRP doors. Foam density 190 – 230 kg/m3. Integrity 38 minutes; Insulation 34 minutes.

Type of document:

Fire Resistance Test
Title:

Fire Resistance Test in Accordance with BS 476: Part 22: 1987 on two single leaf, single acting doorset with glazed apertures.

Identification:

Chilt/ RFO1061 Revision A

Comments:

35 minutes (Vic Half) and 44 minutes integrity (Vic Glazed)