Nitto Kohki Logo Choose Language
 

Made To Order
Vacuum Pumps

VP 0660x2 VP0625 - Photo
Airflow & Power Consumption
Click on each graph to view a larger version
Specifications

VP0660x2 - Airflow Diagram

VP0660x2 - Power Consumption Diagram

VP0660x2 - Exhaust Characteristics Diagram

 

(SI)

(Euro)

(USA)

Attainable Vacuum (series)* -93.3 kPa (-700 mmHg) -933 mbar -27.5 in.Hg
Attainable Vacuum (parallel)* -80 kPa (-600 mmHg) -800 mbar -23.6 in.Hg
Free Air Displacement (series) 25 l/min 0.88 cfm
Free Air Displacement (parallel) 50 l/min 1.77 cfm
Rated Voltage 115 V AC or 230 V AC
Power Consumption 125W or 100W
Rated Frequency 60Hz or 50Hz
Life Expectancy 6,000 hours
Inlet ISO Rc 1/4 female threaded; 2 ports
Outlet ISO Rc 1/4 female threaded; 2 ports
Duty CycleContinuous
Coil Insulation Class B or its equivalent (JETL)
Mounting Dimensions 280 (L) x 130 (W) mm
Gross Weight 10kg 221lbs
Leadwire Length 150mm 5-7/8"
*Operations at higher than -93.3kPa in series or -80kPa in parallel need an additional leak valve or relief valve on the inlet piping.
Application Examples:
VP0660x2 - Application Examples
 
Sketch Drawing and Mounting Dimensions Diagram (mm):